Temperature Calibrators ТС-500; ТС-660

MAIN CHARACTERISTICS ТС-500 ТС-660

Instability maintains the set temperature for 15 minutes. after reaching the set mode in the temperature range, ° С, no more

Vertical gradient in the working zone, ° С / cm, not more

Time to stabilize the temperature at a given point, minutes.

±0,03

0,03

15

±0,03

0,02

15

Limits of permissible basic absolute error of reproduction of the given temperature in the range, ° С:

•from 50 to 100

• from 100 to 200

• from 200 to 400

• from 400 to 500

• from 400 to 500

±0,05

±0,1

±0,2

±0,3

-

in the range at the reference points

±0,05

±0,1

±0,2

±0,3

±0,4

±0,005

±0,02

±0,03

±0,05

±0,07

The heating time to the maximumї

emperature, minutes, no more
90 60
Number of thermometric channels

8 (max diameter 20 mm

8 (max diameter 12 mm)

Height of the thermometric channel, mm

Thermometric channel under the reference

point (center), pieces

The number of ampoules with the reference metal

(gallium, indium, tin, zinc,

aluminum), pieces

Diameter of thermometric channel

ampoules, mm Height of the thermometric channel

ampoules, mm

300



270

1

5

10

180