Temperature Calibrators ТС-500; ТС-660
MAIN CHARACTERISTICS | ТС-500 | ТС-660 | ||
Instability maintains the set temperature for 15 minutes. after reaching the set mode in the temperature range, ° С, no more Vertical gradient in the working zone, ° С / cm, not more Time to stabilize the temperature at a given point, minutes. | ±0,03 0,03 15 | ±0,03 0,02 15 | ||
Limits of permissible basic absolute error of reproduction of the given temperature in the range, ° С: •from 50 to 100 • from 100 to 200 • from 200 to 400 • from 400 to 500 • from 400 to 500 | ±0,05 ±0,1 ±0,2 ±0,3 - | in the range | at the reference points | |
±0,05 ±0,1 ±0,2 ±0,3 ±0,4 | ±0,005 ±0,02 ±0,03 ±0,05 ±0,07 | |||
The heating time to the maximumї emperature, minutes, no more | 90 | 60 | ||
Number of thermometric channels | 8 (max diameter 20 mm | 8 (max diameter 12 mm) | ||
Height of the thermometric channel, mm Thermometric channel under the reference point (center), pieces The number of ampoules with the reference metal (gallium, indium, tin, zinc, aluminum), pieces Diameter of thermometric channel ampoules, mm Height of the thermometric channel ampoules, mm |
300
–
–
–
– | 270
1
5
10 180 |